<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>electrical installations Archives - Siviko</title>
	<atom:link href="https://siviko.com/tag/electrical-installations/feed/" rel="self" type="application/rss+xml" />
	<link>https://siviko.com/tag/electrical-installations/</link>
	<description>Industrial Engineering and Software</description>
	<lastBuildDate>Tue, 07 Aug 2018 07:38:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://siviko.com/wp-content/uploads/2019/10/cropped-favicon-32x32-32x32.png</url>
	<title>electrical installations Archives - Siviko</title>
	<link>https://siviko.com/tag/electrical-installations/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>New generation of multifunction meters for electrical installations</title>
		<link>https://siviko.com/2017/02/10/new-generation-multifunction-meters-for-electrical-installations/</link>
		
		<dc:creator><![CDATA[Viktor Raychev]]></dc:creator>
		<pubDate>Fri, 10 Feb 2017 05:31:09 +0000</pubDate>
				<category><![CDATA[Sonel]]></category>
		<category><![CDATA[electrical installations]]></category>
		<category><![CDATA[MPI-530]]></category>
		<category><![CDATA[multifunction meter]]></category>
		<guid isPermaLink="false">http://siviko.com/?p=2771</guid>

					<description><![CDATA[<p>Multifunction meters for electrical installations gained a wide audience of supporters, who prefer the combination of all measurement functions in one device. Formerly such meters were<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://siviko.com/2017/02/10/new-generation-multifunction-meters-for-electrical-installations/">New generation of multifunction meters for electrical installations</a> appeared first on <a href="https://siviko.com">Siviko</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Multifunction meters for electrical installations gained a wide audience of supporters, who prefer the combination of all measurement functions in one device. Formerly such meters were not handy and the measurements made with them were less accurate, but nowadays the latest multifunction meters often exceed single function meters with their parameters and their small dimensions allowing the user for convenient and ergonomic work.</span></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">Among other meters available on the market Sonel MPI-530 is really impressive. The meter enables performance of the following measurements: electrical anti-shock protection including earth resistance with different methods, earth resistivity and also illuminance, phase rotation and</span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;"> motor rotation. Additionally</span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;"> it enables registration and analysis of voltage, current (including harmonics) and power.</span></span></p>
<p><span style="color: #000000;"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-2772 size-large" style="font-family: helvetica, arial, sans-serif;" src="http://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p-1024x779.jpg" alt="" width="1024" height="779" srcset="https://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p-1024x779.jpg 1024w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p-300x228.jpg 300w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p-768x584.jpg 768w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p-192x146.jpg 192w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p-50x38.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p-99x75.jpg 99w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-P-EN-logger-01_2000p.jpg 2000w" sizes="(max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></span></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">For all measurement functions </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">there is a possibility of evaluation if measurement result holds within specified limits (set by user </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">or coming from the norms).</span></span></p>
<table style="height: 156px;" width="492">
<tbody>
<tr>
<td style="width: 240px;"><img decoding="async" class="aligncenter wp-image-2775" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_01.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_01.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_01-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_01-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_01-113x75.jpg 113w" sizes="(max-width:767px) 300px, 300px" /></td>
<td style="width: 240px;"><img decoding="async" class="aligncenter wp-image-2779" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_02.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_02.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_02-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_02-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_02-113x75.jpg 113w" sizes="(max-width:767px) 300px, 300px" /></td>
</tr>
</tbody>
</table>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;"><strong>Short circuit loop impedance measurement with resolution 0,001 Ω</strong> can be performed in electrical installations all around the world (95..440 V; 45..65 Hz), in L-PE, L-N or L-L circuits. Prospective short circuit current is automatically calculated with (set by user</span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">) nominal voltage or measured voltage. On the screen </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">there are results of short circuit loop impedance, its components, short circuit current, voltage and </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">frequency.</span></span></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-2789" src="http://siviko.com/wp-content/uploads/2018/08/3_qsxytvv.jpg" alt="" width="300" height="189" srcset="https://siviko.com/wp-content/uploads/2018/08/3_qsxytvv.jpg 800w, https://siviko.com/wp-content/uploads/2018/08/3_qsxytvv-300x189.jpg 300w, https://siviko.com/wp-content/uploads/2018/08/3_qsxytvv-768x485.jpg 768w, https://siviko.com/wp-content/uploads/2018/08/3_qsxytvv-231x146.jpg 231w, https://siviko.com/wp-content/uploads/2018/08/3_qsxytvv-50x32.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/3_qsxytvv-119x75.jpg 119w" sizes="auto, (max-width:767px) 300px, 300px" /></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">The measurement is made with “artificial short” method, with several amperes current, which guarantees high accuracy and allows for very short measurement time (10 ms). In case of measurement in networks secured with RCD special measurement function shall be used, which allows for performing the measurement with very small current to ensure that during the measurement the RCD will not trigger. Also in this case full value of impedance is measured and measuring range, according to norm EN 61557, is from 0,5 to 2000 Ω.</span></p>
<p><span style="color: #000000;"><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">Measurement of Residual Current Devices (RCD) type AC, A and B</span></strong></span></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Sonel MPI-530 enables all types of RCD parameters measurement: AC, A, B, general, selective and short-delay, with rated current from 10 mA to 1000 mA. Triggering time and current are measured and additionally touch voltage and resistance of PE conductor; the measurement can start with raising or falling slope (AC current) or can be done with positive or negative value current (unidirectional or DC current).</span></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">The measurements can be performed individually or automatically, where user’s</span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;"> task is to start the measurement and turn on RCD after each triggering. The sequence of this measurement can be expanded with short circuit loop impedance measurement in L-PE circuit, in “RCD” mode (the types of measurements are set by </span></span>user<span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">).</span></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">The automatic measurement offers two modes:</span></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">“Full” where measurement is made with all shapes of measuring current for each type of RCD (AC, A, B) – ex. in case of B type RCD the measurements will be done with four different shapes of measuring current (alternative, unidirectional, unidirectional with constant component and direct);</span><br />
<span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">“Standard” where measurement is made only with chosen shapes of current.</span></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-2782" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_04.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_04.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_04-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_04-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_04-113x75.jpg 113w" sizes="auto, (max-width:767px) 300px, 300px" /></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">The additional function is measurement </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">of triggering time and current during just one activation of measured RCD.</span></span></p>
<p><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Insulation resistance measurement</span></strong></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">The insulation resistance measurement can be performed with one of five test voltages: 50, 100, 250, 500 and 1000 V. The automatic discharge of measured object after each measurement provides safety of user</span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">. The measuring range is up to 10 GΩ.</span></span></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">The measurement can be performed manually, with the use of test leads; automatically in socket, with the use of Uni-Schuko adapter (after single triggering of “Start” button, all combinations of measurements are made) and automatically with the use of special AutoISO adapter – measurements of 3-, 4- and 5-core wires. The adapter automatically switches between following </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">measured circuits (L1-L2, L1-L3, etc.), measuring insulation between all pairs in 3-, 4- and 5-core wires. After the measurement, the object is automatically discharged and the results are saved to meter’s memory.</span></span></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-2777 size-full" src="http://siviko.com/wp-content/uploads/2018/08/dsc2380_XWDZSVW.jpg" alt="" width="800" height="566" srcset="https://siviko.com/wp-content/uploads/2018/08/dsc2380_XWDZSVW.jpg 800w, https://siviko.com/wp-content/uploads/2018/08/dsc2380_XWDZSVW-300x212.jpg 300w, https://siviko.com/wp-content/uploads/2018/08/dsc2380_XWDZSVW-768x543.jpg 768w, https://siviko.com/wp-content/uploads/2018/08/dsc2380_XWDZSVW-206x146.jpg 206w, https://siviko.com/wp-content/uploads/2018/08/dsc2380_XWDZSVW-50x35.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/dsc2380_XWDZSVW-106x75.jpg 106w" sizes="auto, (max-width:767px) 480px, (max-width:800px) 100vw, 800px" /></p>
<p><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Earth resistance measurement</span></strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-2781" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_03.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_03.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_03-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_03-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_03-113x75.jpg 113w" sizes="auto, (max-width:767px) 300px, 300px" /></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">Earth resistance measurement can be performed with the following methods: technical 3-pole, technical 4-pole, technical 3-pole with clamp and two-clamp. 3-pole with clamp and two-clamp methods enable to check multiple earthings </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">without disconnecting; additionally two-clamp method does not require earth probes. The choice of measuring current frequencies enables to eliminate all interferences generated by network voltage.</span></span></p>
<p><img loading="lazy" decoding="async" class="aligncenter size-large wp-image-2774" src="http://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p-681x1024.jpg" alt="" width="681" height="1024" srcset="https://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p-681x1024.jpg 681w, https://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p-200x300.jpg 200w, https://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p-768x1154.jpg 768w, https://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p-97x146.jpg 97w, https://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p-33x50.jpg 33w, https://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p-50x75.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/DSC2309_2000p.jpg 1331w" sizes="auto, (max-width:767px) 480px, 681px" /></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">The unique function is measurement </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">of soil resistivity on different depths (with possibility </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">of choice of distance between earth probes).</span></span></p>
<p><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Continuity measurement of protective and equipotential bondings and resistance measurement</span></strong></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">Before the measurement </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">the resistance of test leads shall be zeroed and later it will be automatically compensated for each measurement. Resistance can be measured with small, 10 mA current with acoustic signaling or with 200 mA current, flowing in both directions (continuity of protective wire measurement according to norms requirements).</span></span></p>
<p><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Protective conductor check</span></strong></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">During measurement of RCD or short circuit loop in L-PE circuit </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">there is a possibility to check if the voltage between touch electrode on the meter and protective conductor PE does not exceed 50 V. The result is read after touching the electrode – if voltage </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">on protective </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">conductor is bigger than 50 V, on the screen there will appear “PE!” sign and acoustic </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">signal will be generated.</span></span></p>
<p><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Phase rotation check and motor rotation check</span></strong></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">For better use of phase rotation and motor rotation tester special adapters for three-phase sockets can be used. There are 7 different types of these adapters, for 16, 32 and 63-amps sockets, which can be also used for measurements of short circuit loop, RCD or insulation resistance.</span></p>
<p><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Registration and analysis of voltage, AC current </span></strong>and<strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;"> power</span></strong></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Sonel MPI-530 enables measurement in real time and registration of voltage and, with the use of additional clamp, also current, power (active, reactive and apparent) and power factor. Depending on the clamp used, maximal measured current can have value of up to 3 kA. There is a choice of two types of hard clamps and three types of flexible clamps, with diameter up to 36 cm. Intuitive module of harmonics analysis for current and voltage (up to 40th) is available.</span></p>
<table>
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter wp-image-2787" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_10.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_10.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_10-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_10-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_10-113x75.jpg 113w" sizes="auto, (max-width:767px) 300px, 300px" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter wp-image-2786" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_09.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_09.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_09-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_09-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_09-113x75.jpg 113w" sizes="auto, (max-width:767px) 300px, 300px" /></td>
</tr>
</tbody>
</table>
<p><strong><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Illuminance measurement</span></strong></p>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">The supplement for meter’s functionality is special adapter – probe with light intensity sensor, enabling illuminance measurements. Thanks to this, apart from electrical measurements and registration, the user has fully functional luxmeter</span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">, enabling light measurements with accordance to norm EN 12464.</span></span></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;"><strong>Memory, PC transmission and creation of measurement reports</strong></span></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Sonel MPI-530 has a brand new concept of memory – it has tree structure with “Client – Premises – Room – Measurement Point” layout. The user has a possibility to save several thousands of measurement results according to the protocol order. Each result can be precisely described (client, premises and point names). This enables to prepare a part of protocol during performance of measurements. Very important and useful for the work of electrician is the possibility of preparation the structure of measurements with “Sonel PE” software. Later, it can be downloaded to meter and the measurements can be performed according to the prepared schedule. If necessary, the structure can be changed during performance of measurements.</span></p>
<table>
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter wp-image-2785" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_08.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_08.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_08-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_08-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_08-113x75.jpg 113w" sizes="auto, (max-width:767px) 300px, 300px" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter wp-image-2783" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_05.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_05.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_05-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_05-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_05-113x75.jpg 113w" sizes="auto, (max-width:767px) 300px, 300px" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter wp-image-2784" src="http://siviko.com/wp-content/uploads/2018/08/mpi530_06.jpg" alt="" width="300" height="200" srcset="https://siviko.com/wp-content/uploads/2018/08/mpi530_06.jpg 240w, https://siviko.com/wp-content/uploads/2018/08/mpi530_06-219x146.jpg 219w, https://siviko.com/wp-content/uploads/2018/08/mpi530_06-50x33.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/mpi530_06-113x75.jpg 113w" sizes="auto, (max-width:767px) 300px, 300px" /></td>
</tr>
</tbody>
</table>
<p><span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">Data can be saved to memory manually after each measurement or automatically. Descriptions of objects, measurement points and </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">clients names can be done using the virtual on-screen keyboard or with the use of additional </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">wireless keyboard (possibility to attach wireless </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">keyboard with hand strap).</span></span></p>
<p><img loading="lazy" decoding="async" class="aligncenter size-large wp-image-2791" src="http://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p-1024x702.jpg" alt="" width="1024" height="702" srcset="https://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p-1024x702.jpg 1024w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p-300x206.jpg 300w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p-768x526.jpg 768w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p-213x146.jpg 213w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p-50x34.jpg 50w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p-109x75.jpg 109w, https://siviko.com/wp-content/uploads/2018/08/MPI-530-pomiar01_2000p.jpg 2000w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">The meter’s memory can be also used in a “classical” way, which means operating only with numbers of memory cells. In this case measurements for each function can be saved in one cell (not necessarily for the same measurement point).</span></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Complete result (main and additional) concerning each measurement or set of measurements with parameters’ settings and time and date of measurement is saved to meter’s memory. The memory can be browsed on the meter’s screen or with the use of computer software. Sonel Reader software (included as standard accessory) enables transmission of memory results to computer (with USB or Bluetooth interface). Optional Sonel PE software enables additionally preparation of object’s structure and preparation of complete report from measurements. Special software Sonel “Foton 12464” is made to prepare the reports from illuminance measurements.</span></p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-2776" src="http://siviko.com/wp-content/uploads/2018/08/dsc2245_I0w6R8K.jpg" alt="" width="532" height="800" srcset="https://siviko.com/wp-content/uploads/2018/08/dsc2245_I0w6R8K.jpg 532w, https://siviko.com/wp-content/uploads/2018/08/dsc2245_I0w6R8K-200x300.jpg 200w, https://siviko.com/wp-content/uploads/2018/08/dsc2245_I0w6R8K-97x146.jpg 97w, https://siviko.com/wp-content/uploads/2018/08/dsc2245_I0w6R8K-33x50.jpg 33w, https://siviko.com/wp-content/uploads/2018/08/dsc2245_I0w6R8K-50x75.jpg 50w" sizes="auto, (max-width:767px) 480px, 532px" /></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Sonel MPI-530 is supplied with complete set of test leads, pin probes, crocodile clips, earth measurement kit, rechargeable battery and carry case. Test leads, pin probes and crocodile clips fulfill the latest, extremely strict standards for safety during the measurement. The meter has efficient dedicated battery, which in combination with the built-in fast charger reduces costs associated with charging. It is also possible to provide power supply through standard battery. Meter continuously monitors the state of charge of the batteries, and when unused switches off automatically (when the auto-off time is set).</span></p>
<p><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif; color: #000000;">Additional accessories to the meter according to your needs could be: one of the five type of clamps for current and power measurement (clamp C-3 can also be used for measuring the earth by clamps</span>,<span style="color: #000000;"><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;"> and in conjunction with clamp broadcasting N-1 for earth resistance measurement method with 2-clamps), AutoISO-1000C adapter, adpaters </span><span style="font-size: 12pt; font-family: helvetica, arial, sans-serif;">and sockets for three-phase industrial contacts (7 types) or additional cables of different lengths.</span></span></p>
<p><span style="font-family: helvetica, arial, sans-serif; font-size: 12pt; color: #000000;"><em>Source: <span style="color: #0000ff;"><a class="_ps2id" style="color: #0000ff;" href="https://www.sonel.pl" data-ps2id-offset="">https://www.sonel.pl</a></span></em></span></p>
<p>The post <a href="https://siviko.com/2017/02/10/new-generation-multifunction-meters-for-electrical-installations/">New generation of multifunction meters for electrical installations</a> appeared first on <a href="https://siviko.com">Siviko</a>.</p>